4-6 2-output Settings ( )
4
Settings for Advanced Functions
4-37
- Digital Fiber Sensor FS-N10 Series User's Manual -
Warning output mode
If output 2 is set to "ALrt" (warning output mode), output 2 turns on (or off if the output
condition is set to N.C.) when either of the following errors occur:
Correction error in DATUM1 or DATUM 2 mode
END-APC error
For error recovery procedures, see "Troubleshooting" (page 6-2).
Refer to page 4-3 "2-output Settings ( )" for setting methods.