Keyence LS-3100/3100W Series Manuale Utente Pagina 37

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 36
31
CHAPTER 4 Functions and Controls
1. Press SEG to display the current segment pair (on the subdisplay).
2. Each time you press SET, the subdisplay will sequentially show "DIA",
"EDGE1", "EDGE2", "(m,n)", then "DIA" again. Display the desired seg-
ment pair. You do not need to press any other key. (When two scanning
heads are used, the subdisplay will sequentially show "DIA", "EDGE1",
"EDGE2", "(m,n)", "2:DIA", "2:EDGE1", "2:EDGE2", "2:(m,n)", and "DIA"
again.)
3. To measure the distance between two desired edges, select the (m,n)
mode.
4. Use SET to display "(m,n)" first.
5. Enter the desired edge numbers.
See the example of operation given below for details.
6. Press ENT to register.
Procedure
Example of Operation You are to measure the gap between two round bars (between edges 3 and
4). Suppose that the currently registered edges are 2 and 3.
Step Key operation Display
1 Press SEG.
2 Use SET to display current
edges (2 and 3).
3 Press "3".
4 Press ".".
5 Press "4".
6 Press ENT.
SEG D I A
S E G ( 5, 2 )
SEG ( ,
)
nm
SEG D I A
SEG ( 2 , 3 )
SEG ( 3 , 3 )
SEG ( 3 , 3 )
SEG ( 3 , 4 )
SEG ( 3 , 4 )
ls3100_30_48.p65 08.10.1, 10:55 AM31